Error codeA.320
Regeneration energy exceeds the capacity of the regeneration resistor. The manual's first action is: “Zero‑speed stop.”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Regeneration overload (A.320)
- Type
- Error code
- Source
- Manual p. 289
What A.320 means
Regeneration overload p. 289
Common causes
- Regeneration energy exceeds the capacity of the regeneration resistor. p. 289
- Occurs when the control power is turned on. p. 289
- Occurs when the main‑circuit power is turned on. p. 289
- Occurs during normal operation with a large temperature rise of the regeneration resistor. p. 289
- Occurs during normal operation with a small temperature rise of the regeneration resistor. p. 289
- Occurs when the servo motor decelerates. p. 289
What to do
- Zero‑speed stop. p. 289
- Replace the servo unit. p. 289
- Calibrate voltage. p. 289
- Select a different regeneration resistor capacity or re‑evaluate load and operating conditions. p. 289
- Calibrate the user‑parameter setting Pn600. p. 289
Before you service the product, read the safety instructions in the manual p. 292.
If A.320 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A.320; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.