Error codeA.400
Main‑circuit DC voltage is abnormally high. The manual's first action is: “DB stop.”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Overvoltage (A.400)
- Type
- Error code
- Source
- Manual p. 289
What A.400 means
Overvoltage p. 289
Common causes
- Main‑circuit DC voltage is abnormally high. p. 289
- Occurs when the main‑circuit power is turned on. p. 289
- AC supply voltage exceeds 290 V. p. 289
- Servo unit failure. p. 289
- Check AC supply voltage (for excessive voltage fluctuations). p. 289
- High speed operation with load inertia too large (insufficient regeneration capability). p. 289
- High speed operation with load inertia too large. p. 289
What to do
- DB stop. p. 289
- Replace the servo unit. p. 289
- Adjust AC supply voltage to the normal range. p. 289
- Re‑evaluate load and operating conditions (check load inertia and specifications of negative load). p. 289
- Re‑evaluate load and operating conditions. p. 289
Before you service the product, read the safety instructions in the manual p. 292.
If A.400 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A.400; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.