YASKAWA III series SGM/SGDS Error A.400: Overvoltage

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Error codeA.400

Main‑circuit DC voltage is abnormally high. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
Overvoltage (A.400)
Type
Error code
Source
Manual p. 289

What A.400 means

Overvoltage p. 289

Common causes

  • Main‑circuit DC voltage is abnormally high. p. 289
  • Occurs when the main‑circuit power is turned on. p. 289
  • AC supply voltage exceeds 290 V. p. 289
  • Servo unit failure. p. 289
  • Check AC supply voltage (for excessive voltage fluctuations). p. 289
  • High speed operation with load inertia too large (insufficient regeneration capability). p. 289
  • High speed operation with load inertia too large. p. 289

What to do

  1. DB stop. p. 289
  2. Replace the servo unit. p. 289
  3. Adjust AC supply voltage to the normal range. p. 289
  4. Re‑evaluate load and operating conditions (check load inertia and specifications of negative load). p. 289
  5. Re‑evaluate load and operating conditions. p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.400 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.400; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.