YASKAWA III series SGM/SGDS Error A.0b0: Servo ON command invalid alarm

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Alarm codeA.0b0

After using an operator function that can turn the servo ON, a control command was used to turn the servo ON. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
Servo ON command invalid alarm (A.0b0)
Type
Alarm code
Source
Manual p. 289

What A.0b0 means

Servo ON command invalid alarm p. 289

Common causes

  • After using an operator function that can turn the servo ON, a control command was used to turn the servo ON. p. 289
  • After using any of the following functions, a JOG run (Fn002), home search (Fn003), program JOG run (Fn004), advanced auto‑tuning (Fn017), or EasyFFT (Fn019) occurs when the servo is turned ON. p. 289

What to do

  1. DB stop. p. 289
  2. Power cycle the unit (turn the power off and on again). p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.0b0 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.0b0; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.