YASKAWA III series SGM/SGDS Error A.330: Main‑circuit wiring error

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Error codeA.330

The main‑circuit power supply method does not match the setting of user parameter Pn001. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
Main‑circuit wiring error (A.330)
Type
Error code
Source
Manual p. 289

What A.330 means

Main‑circuit wiring error p. 289

Common causes

  • The main‑circuit power supply method does not match the setting of user parameter Pn001. p. 289
  • Occurs when the main‑circuit power is turned on. p. 289
  • In DC input mode, AC power is supplied via L1 and L2 (or L1, L2, and L3). p. 289
  • In AC input mode, DC power is supplied via B1/⊕1 and the ⊕ terminal. p. 289
  • Because the regeneration resistor is not connected, Pn600 is not zero. p. 289

What to do

  1. DB stop. p. 289
  2. Replace the servo unit. p. 289
  3. When using AC input, set Pn001.2 = 0. p. 289
  4. When using DC input, set Pn001.2 = 1. p. 289
  5. Set Pn600 = 0. p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.330 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.330; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.