Error codeA.330
The main‑circuit power supply method does not match the setting of user parameter Pn001. The manual's first action is: “DB stop.”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Main‑circuit wiring error (A.330)
- Type
- Error code
- Source
- Manual p. 289
What A.330 means
Main‑circuit wiring error p. 289
Common causes
- The main‑circuit power supply method does not match the setting of user parameter Pn001. p. 289
- Occurs when the main‑circuit power is turned on. p. 289
- In DC input mode, AC power is supplied via L1 and L2 (or L1, L2, and L3). p. 289
- In AC input mode, DC power is supplied via B1/⊕1 and the ⊕ terminal. p. 289
- Because the regeneration resistor is not connected, Pn600 is not zero. p. 289
What to do
- DB stop. p. 289
- Replace the servo unit. p. 289
- When using AC input, set Pn001.2 = 0. p. 289
- When using DC input, set Pn001.2 = 1. p. 289
- Set Pn600 = 0. p. 289
Before you service the product, read the safety instructions in the manual p. 292.
If A.330 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A.330; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.