YASKAWA III series SGM/SGDS Error A.04A: User parameter setting error 2

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Error codeA.04A

User‑parameter value exceeds its allowed range. The manual's first action is: “DB stop.”

Model
YASKAWA III series SGM/SGDS
Display shows
User parameter setting error 2 (A.04A)
Type
Error code
Source
Manual p. 289

What A.04A means

User parameter setting error 2 p. 289

Common causes

  • User‑parameter value exceeds its allowed range. p. 289
  • Occurs when the control power is turned on. p. 289

What to do

  1. DB stop. p. 289
  2. Servo‑unit EEPROM or peripheral circuit failure – replace the servo unit. p. 289

Before you service the product, read the safety instructions in the manual p. 292.

If A.04A is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A.04A; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.