Yaskawa FS100 Error 4352: TWIN DRIVE OVER DEVIATION

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Error code4352

The TWIN DRIVE OVER DEVIATION alarm indicates an axis deviation exceeding limits. The manual's first action is: “(1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS.BIN before replace controller to be safe.”

Model
Yaskawa FS100
Display shows
TWIN DRIVE OVER DEVIATION (4352)
Type
Error code
Source
Manual p. 227

What 4352 means

TWIN DRIVE OVER DEVIATION p. 227

Common causes

  • Sub Code: Signifies the axis in which the alarm occurred p. 227
  • Connection failure p. 227
  • Cable (failure) (motor power cable) p. 227
  • Cable (failure) (motor brake cable) p. 227
  • Servo control board failure p. 227
  • Module failure (amplifier) p. 227
  • Module failure (motor) p. 227

What to do

  1. (1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS.BIN before replace controller to be safe. p. 227
  2. (1)Check U-, V- and W-phase of the motor power cable disconnection. (2)If disconnection is found, replace the motor power cable. p. 227
  3. (1) Check that the motor brake wire is not disconnected. (2) If disconnected, replace the motor brake wire. p. 227

If 4352 is still not resolved

  • (1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS.BIN before replace controller to be safe. p. 227
    “(1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS.BIN before replace controller to be safe.”

This page summarises what the manufacturer’s manual says about 4352; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.