Invalid file name error occurs when the entered file name is invalid. The manual's first action is: “Modify the file name.”
FTP PAR setting error happens due to incorrect FTP settings. The manual's first action is: “Reconfirm FTP related settings.”
HMI data transmission error occurs when data transmission through HMI fails. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
HMI file transmission error happens when files cannot be transmitted via HMI. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
MLC interface memory area error occurs due to an issue with the MLC interface memory area. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
HMI interface communication port error happens when the HMI interface communication port fails. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
HMI interface memory area error occurs due to a failure in the HMI interface memory area. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
HMI interface command area error happens when the system fails to create the HMI interface command area. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
HMI communication memory area creating error occurs when the system cannot create the HMI communication memory area. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
HMI communication interface establishing error happens when the system fails to establish HMI communication. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
Internal comm. error occurs due to communication issues between MLC and NC bottom layer. The manual's first action is: “Use the correct firmware version.”
Non-volatile memory error indicates a failure in the system's non-volatile memory storage. The manual's first action is: “Restart the CNC controller or send it back for servicing.”
DMCNET initialization error happens when the DMCNET cable is not securely connected. The manual's first action is: “Make sure the DMCNET cable is securely connected.”
Servo axis PAR type error occurs due to parameter setting errors. The manual's first action is: “Check the parameter settings.”
A servo axis does not exist error occurs due to incorrect parameter settings for the servo axis. The manual's first action is: “Check the parameter settings.”