The software panel failed to open the external device driver due to a DLL error. The manual's first action is: “Update the software panel to reload the external device driver.”
The connection between the software panel and external device has been disconnected, requiring check of connection settings. The manual's first action is: “Check the connection settings between the controller and the …
The CNC controller’s battery power is insufficient, requiring replacement of the battery. The manual's first action is: “Replace the battery of the CNC controller.”
A system update has completed and requires restarting the CNC controller to apply changes. The manual's first action is: “Restart the CNC controller.”
The machine is approaching its usage duration limit and requires manufacturer contact for unlocking or extension. The manual's first action is: “Contact the equipment manufacturer to unlock or extend the machine usage…
The software panel failed to load the external device driver due to a DLL loading error. The manual's first action is: “Update the software panel to reload the external device driver.”
System parameters have been set beyond their allowable range, requiring value adjustment. The manual's first action is: “Check and modify the parameter values.”
The machine is locked due to expired usage duration and requires manufacturer contact for unlocking or extension. The manual's first action is: “Contact the equipment manufacturer to unlock or extend the machine usage…
The machine failed to backup data because the CF card is not inserted correctly or lacks sufficient space. The manual's first action is: “Confirm that the CF card is inserted correctly and has sufficient space.”
PAR backup failed error happens when the system fails to back up parameters due to incorrect CF card insertion or insufficient space. The manual's first action is: “Confirm that the CF card is inserted correctly and h…
CF card read failed error occurs when no CF card is inserted or it is invalid. The manual's first action is: “Make sure the CF card is correctly installed or replace the CF card.”
MLC PRG error occurs when the MLC program memory area is corrupted or invalid. The manual's first action is: “Reload the MLC program or send the CNC controller back for servicing.”
Internal PAR CRC error happens due to errors in the system's parameter memory area. The manual's first action is: “Use the recovery function of the CNC controller or send the controller back for servicing.”
Memory error indicates an internal memory area failure in the system. The manual's first action is: “Use the recovery function of the CNC controller or send the controller back for servicing.”
Exceeded subroutine call LVL error occurs when a macro call exceeds 8 layers. The manual's first action is: “Check the macro program.”