The camcorder has detected an internal malfunction indicated by error code E02. The manual's first action is: “When an error indication appears, the camcorder turns off automatically. Remove the power supply (battery,…
The error indications (E01 – E06) show what type of malfunction has occurred. The manual's first action is: “When an error indication appears, the camcorder turns off automatically. Remove the power supply (battery, e…
An error indication (E01 - E06) appears. The manual's first action is: “Remove the power supply (battery pack, etc.) and wait a few minutes for the indication to clear. When it does, you can resume using the camcorder…
All 6 error codes of the JVC LYT0384-001A digital video camera with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Ceramic plate temperature sensor failure--invalid . (F5 for 1#,F8 for2#) The manual's first action is: “Check the connection or replace the ceramic plate temperature sensor.”
The supply voltage is above the rated voltage. The manual's first action is: “Please inspect whether power supply is normal. Power on after the power supply is normal.”
The supply voltage is below the rated voltage. The manual's first action is: “Please inspect whether power supply is normal. Power on after the power supply is normal.”
The IGBT has reached a high temperature. The manual's first action is: “Touch "ON/OFF" button to restart unit. Wait for the temperature of IGBT return to normal. Check whether the fan runs smoothly; if not, replace th…
Temperature sensor of the IGBT failure. (short circuit) The manual's first action is: “Replace the power board.”
Temperature sensor of the IGBT failure. (open circuit) The manual's first action is: “Replace the power board.”
The ceramic plate sensor is overheating. The manual's first action is: “Touch "ON/OFF" button to restart unit. Wait for the temperature of ceramic plate return to normal.”
Ceramic plate temperature sensor failure--short circuit The manual's first action is: “Check the connection or replace the ceramic plate temperature sensor.”
Ceramic plate temperature sensor failure--open circuit The manual's first action is: “Check the connection or replace the ceramic plate temperature sensor.”
All 9 error codes of the Fujioh FH-IC6020 Fujioh FH-IC6020 with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
ADC Overflow encountered during AUX measurement The manual lists no action for this code.