Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Potentiometer Error indicates a malfunction with the potentiometer assembly board. The manual's first action is: “Problem of potentiometer (Potentiometer Ass'y. Board)”
Coil No.2 Bias High similarly leads to slow valve response and incorrect position. The manual's first action is: “Valve is not closed or open and moves slowly.”
Coil No.2 Bias Low results in slow valve operation and improper positioning. The manual's first action is: “Valve is not closed or open and moves slowly.”
Coil No.1 Bias High also causes valve movement to be slow and position inaccurate. The manual's first action is: “Valve is not closed or open and moves slowly.”
Coil No.1 Bias Low means valve movement is slow and position is incorrect. The manual's first action is: “Valve is not closed or open and moves slowly.”
PST error displays BAD on the screen, indicating a system fault. The manual's first action is: “BAD is shown.”
HART Rx error signals a failure in HART communication. The manual's first action is: “HART signal failure”
Operating angle out of range triggers auto-calibration failure during step 4. The manual's first action is: “MONT is shown during step 4 and an auto-calibration process is finished without completion.”
Feedback error (2 - 9%) indicates the valve operates with insufficient stroke, causing sluggish movement. The manual's first action is: “The operating stroke is too small and the valve doesn't work smoothly.”
Feedback error (0 - 1%) shows auto-calibration failed without completing step 4. The manual's first action is: “PM00 is shown at step 4 and an auto-calibration is finished without completion.”
High input current(20.5mA) means the 4–20mA signal is too strong, causing LCD display issues. The manual's first action is: “Data on LCD are shown too dim or too bright.”
Low input current (3.7mA) indicates the 4–20mA signal is too weak. The manual's first action is: “Re-check 4 – 20mA input signals.”
All 13 error codes of the Power-Genex SS5L / SS5R Series smart valve positioner with their meaning, causes and what to do, taken from the manufacturer's manual with page references.