Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Speed Control Optimisation Failure indicates motor data identification failed, or timeout waiting for stable speed or inconsistent readings. The manual lists no action for this code.
Motor Data Identification Failure indicates motor data identification failed, possibly due to missing load or current limit reached during identification. The manual lists no action for this code.
Auto restart after n means auto restart attempts have exceeded the value set in p1211. The manual lists no action for this code.
EM brake overcurrent indicates an overcurrent condition in the electromagnetic brake. The manual's first action is: “Quit fault eg. via DI2”
Power limit exceeded during regeneration occurs when motor is driven by active load causing excessive regeneration, or at high load inertias during ramp down. The manual's first action is: “Reduce regeneration from ac…
Overcurrent on W phase indicates over current trip on W phase or earth fault. The manual's first action is: “Quit fault eg. via DI2”
Supply to Gate Driver Not Enabled means gate driver not enabled, possibly due to synchronization error of safety state machines. The manual's first action is: “Contact Service Department.”
F3E Dclink Ripple indicates large ripples on the dclink. The manual's first action is: “Contact Service Department.”
The Siemens CU240S detected an output phase fault due to one output phase being disconnected. The manual's first action is: “Check motor connection.”
The Siemens CU240S experienced a powerstack hardware fault from IGBT short circuit or chopper short circuit, requiring service department contact and replacement of the inverter module. The manual's first action is: “…
The Siemens CU240S detected an earth fault due to phase current sum exceeding 5% of nominal inverter current. The manual lists no action for this code.
The Siemens CU240S detected a missing mains phase when pulses are enabled and drive is loaded. The manual's first action is: “Check the input wiring of the mains phases.”
The Siemens CU240S lost the motor temperature signal, likely due to an open or short circuit in the sensor, and switched to thermal model monitoring. The manual's first action is: “Check the following: • the connectio…
The Siemens CU240S experienced a chip temperature rise exceeding critical levels, possibly from high startup load, large load steps, or too fast ramp-up rates. The manual's first action is: “Remedy: Check the followin…
The Siemens CU240S detected excessive I2T (current squared time) due to an overloaded inverter or demanding load cycle. The manual's first action is: “Remedy: Check the following: • Load cycle must lie within specifie…