Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Control Panel setpoint fault occurs when no setpoint values are received from the Control Panel during a period when communication is off. The manual's first action is: “Check and improve - if necessary - the value in…
USS Setpoint Fault happens when no setpoint values are received from USS during a period when communication is off. The manual's first action is: “Check USS master”
USS setpoint fault occurs when no setpoint values are received from USS during a period when communication is off. The manual's first action is: “Check and if necessary improve the monitoring time in the STARTER SW wh…
PLC setpoint fault means no setpoint values are received from PLC during telegram off time. The manual's first action is: “Check and improve - if necessary - the value in p2040”
Drive attempted to do an automatic clone during startup indicates no Clone00.bin file is present in the correct directory. The manual's first action is: “If a automatic clone is required: - Insert MMC with correct Fil…
Par Cl. MMC-PS contents incompatible means file exists but was created for a different drive type. The manual's first action is: “Ensure clone from compatible drive type.”
Par Cl. MMC-PS contents invalid indicates file exists but contains corrupted control word data. The manual's first action is: “Recopy and ensure operation completes.”
Par Cl. MMC-PS not fitted Fault means the MMC-PS is not connected or incorrect type, or cannot write to MMC. The manual lists no action for this code.
Asic Timeout indicates internal communications failure, possibly due to hardware or software link failures. The manual's first action is: “Check connection between inverter power module and inverter control unit”
BOP contents incompatible indicates attempt to initiate parameter cloning with a BOP created for another drive type. The manual's first action is: “Download to BOP from this type of drive.”
BOP fault means parameter cloning was attempted with an empty or invalid BOP. The manual's first action is: “Download to BOP or replace BOP.”
BOP not fitted indicates attempt to initiate parameter cloning without the BOP being installed. The manual's first action is: “Fit BOP and try again.”
BOP-EEPROM Fault means read or write failure while saving non-volatile parameters to EEPROM on BOP during parameter cloning. The manual's first action is: “Factory Reset and new parameterization”
power stack Fault indicates read failure for power stack information or invalid data. The manual's first action is: “Check connection between inverter power module and inverter control unit”
Parameter EEPROM Fault means read or write failure while accessing the EEPROM, possibly due to it being full from too many parameter changes. The manual's first action is: “OFF 2”