The Siemens CU240S experienced inverter over-temperature, likely from overload, inadequate ventilation, high pulse frequency, ambient heat, or a non-functioning fan. The manual's first action is: “Remedy: Check the fo…
The Siemens CU240S detected an undervoltage condition due to a failed main supply or shock load exceeding limits. The manual's first action is: “Quit fault eg. via D12”
The Siemens CU240S detected an overvoltage condition caused by high mains voltage or regenerative mode operation. The manual's first action is: “Quit fault eg. via D12”
The Siemens CU240S detected an overcurrent condition due to motor power mismatch or a short circuit in the motor leads. The manual's first action is: “Quit fault eg. via D12”
Recent fault trip -1, fault 1 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 8 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 7 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 6 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 5 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 4 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 3 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 2 occurred on the Siemens CU240S. The manual lists no action for this code.
Recent fault trip - fault 1 occurred on the Siemens CU240S. The manual lists no action for this code.
All 87 error codes of the Siemens CU240S Siemens CU240S with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Coil Error signals a problem with the coil component. The manual's first action is: “Problem of coil”