Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The servo power for the job has been turned off due to a setting error. The manual's first action is: “- Turn OFF the servo power supply, and then turn ON the servo power supply for the group axis to be operated.”
The servo power for the job has been turned off due to a setting error. The manual's first action is: “(1)Check the following settings. - Turn OFF the servo power supply, and then turn ON the servo power supply for th…
A software operation error occurred in the system. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yask…
A software operation error occurred in the system. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yask…
A software operation error occurred in the system. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yask…
A software operation error occurred during job access. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your …
A software operation error occurred. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representa…
H A function error (conv_pulse_to_angle()) occurred due to a software operation error. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintena…
H A function error (conv_shift_data()) indicates a setting error. The manual's first action is: “(1)Check the following settings. - Correct the job so that the target position data is within the motion range. (2)If th…
H A function error (conv_pos_data()) indicates a setting error. The manual's first action is: “(1)Check the following settings. - Correct the job so that the target position data is within the motion range. (2)If the …
File C1 through C3 for conveyor calibration not set The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yas…
File C1 through C3 for calibration between manipulators not set The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then cont…
Conversion completion status for AXIS section feedback latch data not established The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance m…
Output buffer SYSCON for automatic test data in use The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yas…
A software operation error occurred in the base axis file type. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then cont…