Encoder converter unit 2 automatic adjustment error means an abnormal signal from the PLG was detected during automatic adjustment, or a connector is disconnected or not disconnected. The manual's first action is: “PR”
Encoder converter unit 2 communication error means an error was detected in the communication with the serial output linear scale for the servo or communication failure with the MDS-B-PJEX spindle. The manual's first …
Detector converter unit 2 connection error means an error was detected in the connection with the analog output linear scale for the servo or initial communication failure with the MDS-B-PJEX spindle. The manual's fir…
Watch dog alarm occurs when system operation is abnormal, version was changed, or not changed. The manual's first action is: “Replace with a drive unit containing the original software version.”
Power reboot request alarm is triggered by a mismatch in program mode selection or high-gain parameters during startup. The manual's first action is: “Turn the drive unit power ON again.”
Power module overheating occurs when the power module’s temperature protection activates or fan fails to rotate properly. The manual's first action is: “AR”
External emergency stop setting error occurs when rotary switch settings mismatch parameter settings. The manual's first action is: “AR”
Overvoltage alarm is triggered when main circuit PN bus voltage exceeds tolerable levels. The manual's first action is: “NR”
Regenerative resistor overheating occurs when the temperature protection function activates in the resistor. The manual's first action is: “PR”
Over-regeneration alarm triggers when regenerative resistor overload exceeds 100% during motor deceleration. The manual's first action is: “PR”
Instantaneous power failure/external emergency stop occurs during a sudden power loss. The manual's first action is: “NR”
Power supply error occurs if the power supply is disconnected or its A/D converter has failed. The manual's first action is: “AR”
Memory error is detected when an internal memory error occurs. The manual's first action is: “AR”
Parameter error occurs when the power supply unit's capacity isn’t suitable for the regenerative resistor type set in parameters. The manual's first action is: “PR”
Main circuit error is detected when there’s an abnormality in the main circuit capacitor’s charging operation. The manual's first action is: “PR”