Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Control axis removal warning means control axis removal was commanded. The manual's first action is: “*”
Absolute position counter warning means deviation was detected between absolute position data and either absolute or relative position data. The manual's first action is: “*”
Overload warning means overload detection level is 80% or more. The manual's first action is: “*”
Turret indexing error warning means commanded turret indexing position shift amount is outside specified range or setting is incorrect. The manual's first action is: “*”
Battery voltage drop means the battery supplying to the absolute position detector has dropped but data is held. The manual's first action is: “*”
Absolute position detector, multi-rotation counter error means an error was detected in the multi-rotation counter for absolute position detector and compensation is not possible. The manual's first action is: “*”
MP scale offset error means an error was detected in the offset data received from the MP scale for MP scale absolute position detection system. The manual's first action is: “PR”
MP scale feedback error means excessive deviation was detected in motor end detector and MP scale feedback data for MP scale absolute position detection system. The manual's first action is: “PR”
Initial absolute position fluctuation means the position data fluctuated during initial absolute position creation. The manual's first action is: “PR”
Detector, protocol error means an error was detected in data for absolute position detection system, no specific abnormality found, or ambient environment anomaly occurred. The manual's first action is: “*”
Detector, communication error means an error was detected in communication with the detector for absolute position detection system, or connector is disconnected or not disconnected. The manual's first action is: “*”
Detector, initial communication error means initial communication with the absolute position linear scale was not possible or setting is incorrect. The manual's first action is: “PR”
Encoder converter unit 2 data error means a data error was detected with the MDS-B-HR unit. The manual's first action is: “PR”
Encoder converter unit 2 CPU error means a CPU error was detected with the MDS-B-HR servo or MDS-B-PJEX spindle. The manual's first action is: “AR”
Encoder converter unit 2 judgment error means a detector type not within specifications was detected with the MDS-B-PJEX. The manual's first action is: “PR”