The current value is outside the acceptable measuring range. The manual's first action is: “Perform basic setup; Check linearization”
The linearization table has been entered incorrectly. The manual's first action is: “Readjust table”
The probe and electronic insert data are incompatible with each other. The manual's first action is: “Check probe, perform a total reset”
The electronic insert has reached a temperature higher than its maximum sensor limit. The manual's first action is: “Lower ambient temperature by suitable measures”
Level linearization points have been entered incorrectly. The manual's first action is: “Enter additional linearization points”
Calibration is faulty on the device. The manual's first action is: “Correct calibration”
Linearization curve for level is not monotone on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Re-enter linearization”
Prooftest is currently active on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Wait until the prooftest is completed”
Insulation is defective and a warning has been issued on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Check insulation”
Probe insulation break has been detected on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Verify probe”
Hardware was not recognized after replacement on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Repeat download or perform a total reset.”
Sensor-DAT [EEPROM] data is inconsistent on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Repeat download from electronic insert or perform a total reset”
Download error occurred on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Repeat download or perform a total reset”
Electronics defective on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Switch device off/on; if the error persists, Contact Endress+Hauser-Service”
Electronics defective on the Endress+Hauser FMI51, FMI52. The manual's first action is: “Switch device off/on; if the error persists, Contact Endress+Hauser-Service”