Mitsubishi Electric MDS-C1 Series Error 42: Feedback error 1

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code42

Feedback error 1 occurs when position or PLG feedback signals from servo or spindle are corrupted due to loose connectors or signal issues. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Feedback error 1 (42)
Type
Error code
Source
Manual p. 311

What 42 means

Feedback error 1 p. 311

Common causes

  • With the servo, pulse-type position detector feedback signal error was detected. With the spindle, a PLG feedback signal error was detected. p. 311
  • The connector is disconnected (or loose). p. 311
  • The connector is not disconnected. p. 311
  • There is a connection fault. p. 311
  • The alarm is on the drive unit side. p. 311
  • The alarm is on the detector side. p. 311
  • There is a problem. p. 311
  • No abnormality was found in particular. p. 311

What to do

  1. PR p. 311
  2. Correctly install. p. 311
  3. Investigate item 2. p. 311
  4. Replace the detector cable. p. 311
  5. Replace the drive unit. p. 311
  6. Investigate item 4. p. 311
  7. Adjust the PLG output waveform. p. 311
  8. Replace the detector. p. 311

Before you service the product, read the safety instructions in the manual p. 4.

If 42 is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 42; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.