Error code4E
NC command mode error occurs when an invalid spindle control mode selection is made, causing consistent or irregular alarms. The manual's first action is: “NR”
- Model
- Mitsubishi Electric MDS-C1 Series
- Display shows
- NC command mode error (4E)
- Type
- Error code
- Source
- Manual p. 311
What 4E means
NC command mode error p. 311
Common causes
- A spindle control mode selection exceeding the specifications was input. p. 311
- The alarm always occurs at the same position. p. 311
- The alarm occurs irregularly. p. 311
- The alarm occurs during position control. p. 311
- The alarm occurs during speed control. p. 311
What to do
- NR p. 311
- Check the NC and PLC program process. p. 311
- Investigate item 2. p. 311
- Check the NC and PLC program process. (If the cause cannot be pinpointed, replace the drive unit, and confirm.) p. 311
Before you service the product, read the safety instructions in the manual p. 4.
If 4E is still not resolved
- contact service / dealer p. 5 “Wiring, maintenance and inspection work must be done by a qualified technician.”
This page summarises what the manufacturer’s manual says about 4E; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.