Mitsubishi Electric MDS-C1 Series Error 3D: Spindle speed lock

AC Servo/Spindle · taken from the manufacturer’s manual, pages cited

Error code3D

The spindle speed failed to reach 45r/min even when maximum torque was commanded. The manual's first action is: “PR”

Model
Mitsubishi Electric MDS-C1 Series
Display shows
Spindle speed lock (3D)
Type
Error code
Source
Manual p. 310

What 3D means

Spindle speed lock p. 310

Common causes

  • Even when the maximum torque was commanded, the motor speed does not increase to 45r/min or more. p. 310

What to do

  1. PR p. 310

Before you service the product, read the safety instructions in the manual p. 4.

If 3D is still not resolved

  • contact service / dealer p. 5
    “Wiring, maintenance and inspection work must be done by a qualified technician.”

This page summarises what the manufacturer’s manual says about 3D; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi Electric. Found a mistake? Report an error.