Motor feedback A signal saturated due to defective rotor sensor cabling, encoder or X4 card, or excessive offset/gain settings. The manual's first action is: “Check the cable of the Encoder and that of the X4 card or increase the value of these parameters.”
- Model
- FAGOR MAN REGUL (IN)
- Display shows
- Motor feedback A signal saturated. (603)
- Type
- Error code
- Source
- Manual p. 332
What 603 means
Motor feedback A signal saturated. p. 332
Common causes
- - Defective rotor sensor cabling, encoder or X4 card. The offset and/or gain (RP1, RP2, RP3 and RP4) of the signals is too large. p. 332
What to do
- Check the cable of the Encoder and that of the X4 card or increase the value of these parameters. p. 332
If 603 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact FAGOR service.
This page summarises what the manufacturer’s manual says about 603; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FAGOR. Found a mistake? Report an error.