FAGOR MAN REGUL (IN) Error 603: Motor feedback A signal saturated.

FAGOR MAN REGUL (IN) servo-drive system · taken from the manufacturer’s manual, pages cited

Error code603

Motor feedback A signal saturated due to defective rotor sensor cabling, encoder or X4 card, or excessive offset/gain settings. The manual's first action is: “Check the cable of the Encoder and that of the X4 card or increase the value of these parameters.”

Model
FAGOR MAN REGUL (IN)
Display shows
Motor feedback A signal saturated. (603)
Type
Error code
Source
Manual p. 332

What 603 means

Motor feedback A signal saturated. p. 332

Common causes

  • - Defective rotor sensor cabling, encoder or X4 card. The offset and/or gain (RP1, RP2, RP3 and RP4) of the signals is too large. p. 332

What to do

  1. Check the cable of the Encoder and that of the X4 card or increase the value of these parameters. p. 332

If 603 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact FAGOR service.

This page summarises what the manufacturer’s manual says about 603; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FAGOR. Found a mistake? Report an error.