Direct feedback signals A and/or B too weak due to defective cabling, feedback device, or feedback board (X4/X3), or low parameter values RP1-RP4. The manual's first action is: “Check the cable, the feedback device, the cards or increase the value of these parameters.”
- Model
- FAGOR MAN REGUL (IN)
- Display shows
- Direct feedback signal A and/or B too weak. (608)
- Type
- Error code
- Source
- Manual p. 332
What 608 means
Direct feedback signal A and/or B too weak. p. 332
Common causes
- - Defective cabling, feedback device or feedback board (connector X4 or X3). - The value of parameter RP1, RP2, RP3, or RP4 is too low. p. 332
What to do
- Check the cable, the feedback device, the cards or increase the value of these parameters. p. 332
If 608 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact FAGOR service.