FAGOR MAN REGUL (IN) Error 607: Saturation of the values of direct feedback signal A and/or B.

FAGOR MAN REGUL (IN) servo-drive system · taken from the manufacturer’s manual, pages cited

Error code607

Direct feedback signal saturation due to defective cabling, feedback device, or feedback board (X4/X3), or excessive parameter values RP1-RP4. The manual's first action is: “Check the cable, the feedback device, the cards or decrease the value of these parameters.”

Model
FAGOR MAN REGUL (IN)
Display shows
607
Type
Error code
Source
Manual p. 332

What 607 means

Saturation of the values of direct feedback signal A and/or B. p. 332

Common causes

  • - Defective cabling, feedback device or feedback board (connector X4 or X3). - The value of parameter RP1, RP2, RP3, or RP4 is too high. p. 332

What to do

  1. Check the cable, the feedback device, the cards or decrease the value of these parameters. p. 332

If 607 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact FAGOR service.

This page summarises what the manufacturer’s manual says about 607; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with FAGOR. Found a mistake? Report an error.