Delta VFD-M Series Error OV: Over Voltage

AC motor drive · taken from the manufacturer’s manual, pages cited

Fault codeOV

Over Voltage means the voltage is outside specification or has occurred unexpectedly. The manual's first action is: “Reduce voltage to be within spec.”

Model
Delta VFD-M Series
Display shows
Over Voltage (OV)
Type
Fault code
Source
Manual p. 123

What OV means

Over Voltage p. 123

Common causes

  • Is voltage within specification p. 123
  • Has over-voltage occurred without load p. 123
  • Dose OV occur when sudden acceleration stops p. 123
  • Increase acceleration time p. 123
  • Use braking unit or DC braking p. 123

What to do

  1. Reduce voltage to be within spec. p. 123
  2. When OV occurs, check if the voltage of DC BUS is greater than protection value p. 123
  3. Increase deceleration time p. 123
  4. Reduce moment of inertia p. 123
  5. Need to check control method. Please contact DELTA. p. 123

Before you service the product, read the safety instructions in the manual p. 4.

If OV is still not resolved

  • contact your dealer p. 4
    “If you have any questions, please contact your dealer.”