Fault codeGFF
Ground fault means the AC drive output is grounded, which may damage the power module. The manual's first action is: “Remove ground fault”
- Model
- Delta VFD-M Series
- Display shows
- Ground fault (GFF)
- Type
- Fault code
- Source
- Manual p. 123
What GFF means
Ground fault p. 123
Common causes
- Is output circuit(cable or motor) of AC motor drive grounded? p. 123
- Ground fault: The AC drive output is abnormal. When the output terminal is grounded (short circuit current is 50% more than the AC drive rated current), the AC drive power module may be damaged. The short circuit protection is provided for AC drive protection, not user protection. p. 123
What to do
- Remove ground fault p. 123
- Ground fault: 1. Check whether the IGBT power module is damaged. 2. Check for possible poor insulation at the output line. p. 123
Before you service the product, read the safety instructions in the manual p. 4.
If GFF is still not resolved
- contact your dealer p. 4 “If you have any questions, please contact your dealer.”