Delta VFD-M Series Error OU: The AC drive detects that the DC bus voltage has exceeded its maximum allowable value.

AC motor drive · taken from the manufacturer’s manual, pages cited

Fault codeOU

The AC drive detects that the DC bus voltage has exceeded its maximum allowable value. The manual's first action is: “1. Check whether the input voltage falls within the rated AC drive input voltage.”

Model
Delta VFD-M Series
Display shows
OU
Type
Fault code
Source
Manual p. 132

What OU means

The AC drive detects that the DC bus voltage has exceeded its maximum allowable value. p. 132

What to do

  1. 1. Check whether the input voltage falls within the rated AC drive input voltage. p. 132
  2. 2. Check for possible voltage transients. p. 132
  3. 3. Bus over-voltage may also be caused by motor regeneration. Either increase the decel time or add an optional brake resistor. p. 132
  4. 4. Check whether the required braking power is within the specified limits. p. 132

Before you service the product, read the safety instructions in the manual p. 4.

If OU is still not resolved

  • contact your dealer p. 4
    “If you have any questions, please contact your dealer.”

This page summarises what the manufacturer’s manual says about OU; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.