Delta VFD-M Series Error OL: The AC drive detects excessive drive output current.

AC motor drive · taken from the manufacturer’s manual, pages cited

Error codeOL

The AC drive detects excessive drive output current, possibly due to load or noise. The manual's first action is: “Check for correct settings at Pr. 58 and Pr.59”

Model
Delta VFD-M Series
Display shows
The AC drive detects excessive drive output current. (OL)
Type
Error code
Source
Manual p. 125

What OL means

The AC drive detects excessive drive output current. p. 125

Common causes

  • OL1/OL2 p. 125
  • Is load too large p. 125
  • Maybe AC motor drive has malfunction or misoperation due to noise p. 125
  • Note: The AC drive can withstand up to 150% of the rated current for a maximum of 60 seconds. p. 125

What to do

  1. Check for correct settings at Pr. 58 and Pr.59 p. 125
  2. Reduce load or increase the power of AC motor drive p. 125
  3. Modify setting p. 125
  4. 1. Check whether the motor is overloaded. 2. Reduce torque compensation setting as set in Pr.54. 3. Increase the AC drive's output capacity. p. 125

Before you service the product, read the safety instructions in the manual p. 4.

If OL is still not resolved

  • contact your dealer p. 4
    “If you have any questions, please contact your dealer.”

This page summarises what the manufacturer’s manual says about OL; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.