Delta VFD-M Series Error oH: The AC drive temperature sensor detects excessive heat.

AC motor drive · taken from the manufacturer’s manual, pages cited

Fault codeoH

The AC drive temperature sensor detects excessive heat, possibly due to ambient temperature or blocked ventilation. The manual's first action is: “1. Ensure that the ambient temperature falls within the specified temperature range. 2. Make sure that the ventilation holes are not obstructed. 3. Remove any foreign objects on the heat sinks and check for possible dirty heat sink fins. 4. Provide enough spacing for adequate ventilation.”

Model
Delta VFD-M Series
Display shows
The AC drive temperature sensor detects excessive heat. (oH)
Type
Fault code
Source
Manual p. 133

What oH means

The AC drive temperature sensor detects excessive heat. p. 133

What to do

  1. 1. Ensure that the ambient temperature falls within the specified temperature range. 2. Make sure that the ventilation holes are not obstructed. 3. Remove any foreign objects on the heat sinks and check for possible dirty heat sink fins. 4. Provide enough spacing for adequate ventilation. p. 133

Before you service the product, read the safety instructions in the manual p. 4.

If oH is still not resolved

  • contact your dealer p. 4
    “If you have any questions, please contact your dealer.”

This page summarises what the manufacturer’s manual says about oH; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.