An overload error occurs when the servo motor or drive is overloaded during operation or startup. The manual's first action is: “Check if the drive is overloaded. Increase motor capacity or reduce load.”
- Model
- Delta ASDA-B series
- Display shows
- Overload (ALE 6)
- Type
- Error code
- Source
- Manual p. 256
What ALE 6 means
Overload p. 260
Common causes
- Servo motor and drive is overload. p. 260
- When the motor is started within 30 minutes: p. 260
- The drive has exceeded its rated load during continuous operation. p. 260
- Control system parameter setting is incorrect. p. 260
- The wiring of drive and encoder is in error. p. 260
- The encoder of the motor is damaged. p. 260
- The connection of U, V, W is incorrect. p. 260
- When the motor start running for 3 minutes above: p. 260
What to do
- Check if the drive is overloaded. Increase motor capacity or reduce load. p. 260
- Check if there is mechanical vibration Adjust gain value of control circuit. Accel/Decel time setting is too fast. Decrease Accel/Decel time setting. p. 260
- Check the wiring of U, V, W and encoder. Ensure all wiring is correct. p. 260
- Please contact your distributor for assistance or contact with Delta. p. 260
- Ensure the U, V, W of the motor is connected to the U, V, W of the drive correctly. Ensure all wiring is correct. p. 260
- Turn ARST (DI signal) ON to clear the fault or restart the servo drive. p. 260
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 6 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 6; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.