A regeneration error occurs when regeneration control is faulty, the servo drive hardware is damaged, or the regenerative resistor is not connected. The manual's first action is: “Please contact your distributor for assistance or contact with Delta.”
- Model
- Delta ASDA-B series
- Display shows
- Regeneration error (ALE 5)
- Type
- Error code
- Source
- Manual p. 256
What ALE 5 means
Regeneration error p. 259
Common causes
- Regeneration control operation is in error. p. 259
- Servo drive hardware is damaged. p. 259
- Regenerative resistor is not connected. p. 259
- The transistor for regeneration is disabled. p. 259
- Parameter setting is in error. p. 259
What to do
- Please contact your distributor for assistance or contact with Delta. p. 259
- Check the wiring connection of regenerative resistor. Reconnect regenerative resistor. p. 259
- Check if the transistor for regeneration is short-circuited. Please contact your distributor for assistance or contact with Delta. p. 259
- Confirm the parameter setting and specifications of regenerative resistor. Correctly reset parameter again. p. 259
- Turn ARST (DI signal) ON to clear the fault or restart the servo drive. p. 259
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 5 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 5; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.