Delta ASDA-B series Error ALE 4: Z Pulse shift

Delta ASDA-B series · taken from the manufacturer’s manual, pages cited

Error codeALE 4

A Z pulse shift error occurs when the magnetic field angle of the Z phase is incorrect, or the encoder is damaged or loose. The manual's first action is: “Check Encoder for the damage. Repair or replace the motor.”

Model
Delta ASDA-B series
Display shows
Z Pulse shift (ALE 4)
Type
Error code
Source
Manual p. 256

What ALE 4 means

Z Pulse shift p. 259

Common causes

  • The corresponding angle of magnetic field of Z phase is error. p. 259
  • Encoder is damage. p. 259
  • Encoder is loose. p. 259

What to do

  1. Check Encoder for the damage. Repair or replace the motor. p. 259
  2. Examine the Encoder connector. Install the motor again. p. 259
  3. Restart the servo drive. p. 259

Before you service the product, read the safety instructions in the manual p. 3.

If ALE 4 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ALE 4; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.