An overcurrent error occurs when the main circuit current exceeds 1.5 times the motor's instantaneous maximum current. The manual's first action is: “Short-circuit at drive output (U, V, W). 1. Check the wiring connections between drive and motor. 2. Check if the wire is short-circuited. Repair the short-circuited and avoid metal conductor being exposed.”
- Model
- Delta ASDA-B series
- Display shows
- Overcurrent (ALE 1)
- Type
- Error code
- Source
- Manual p. 256
What ALE 1 means
Overcurrent p. 258
Common causes
- Main circuit current is higher than 1.5 multiple of motor's instantaneous maximum current value. p. 258
- When SERVO OFF, but the power is on: p. 258
- When SERVO ON and the cable connected to U, V, W terminal is removed: p. 258
- When SERVO ON and the cable connected to U, V, W terminal is not removed or the servo motor is running: p. 258
What to do
- Short-circuit at drive output (U, V, W). 1. Check the wiring connections between drive and motor. 2. Check if the wire is short-circuited. Repair the short-circuited and avoid metal conductor being exposed. p. 258
- Motor wiring error. Check if the wiring steps are all correct when connecting motor to drive. Follow the wiring steps in the user manual to reconnect wiring. p. 258
- IGBT error or servo hardware is damaged. Heat sink overheated. Please contact your distributor for assistance or contact with Delta. p. 258
- Turn ARST (DI signal) ON to clear the fault or restart the servo drive. p. 258
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.