An overvoltage error occurs when the main circuit voltage exceeds its maximum allowable value. The manual's first action is: “The main circuit voltage has exceeded its maximum allowable value. Use voltmeter to check whether the input voltage falls within the rated input voltage. (For voltage specification, please refer to section 11.1 in Chapter 11). Use correct power supply or stabilizing power.”
- Model
- Delta ASDA-B series
- Display shows
- Overvoltage (ALE 2)
- Type
- Error code
- Source
- Manual p. 256
What ALE 2 means
Overvoltage p. 258
Common causes
- Main circuit voltage has exceeded its maximum allowable value. p. 258
- When SERVO OFF, but the power is on: p. 258
- When SERVO ON: p. 258
What to do
- The main circuit voltage has exceeded its maximum allowable value. Use voltmeter to check whether the input voltage falls within the rated input voltage. (For voltage specification, please refer to section 11.1 in Chapter 11). Use correct power supply or stabilizing power. p. 258
- Power input error. (Incorrect power input) Use voltmeter to check whether the input voltage is within the specified limit. Use correct power supply or stabilizing power. p. 258
- Servo drive hardware may be damaged. The servo drive hardware may be damaged after the users have used voltmeter to check the input voltage falls within the rated input voltage. Please contact your distributor for assistance or contact with Delta. p. 258
- Turn ARST (DI signal) ON to clear the fault or restart the servo drive. p. 258
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 2 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.