A serial communication error occurs when RS-232/485 communication is faulty due to pulse signal or encoder wiring errors. The manual's first action is: “1. Check if all wiring is correct. 2. Check if the users conduct the wiring by the wiring information in the user manual.”
- Model
- Delta ASDA-B series
- Display shows
- Serial communication error (ALE 11)
- Type
- Error code
- Source
- Manual p. 256
What ALE 11 means
Serial communication error p. 262
Common causes
- RS-232/485 serial communication is in error. p. 262
- Pulse signal is in error. p. 262
- The wiring of encoder is in error. p. 262
- Encoder is loose p. 262
- The wiring of encoder is defective. p. 262
- Encoder is damage p. 262
What to do
- 1. Check if all wiring is correct. 2. Check if the users conduct the wiring by the wiring information in the user manual. p. 262
- Examine the encoder connector. p. 262
- Check if all connections are tight. p. 262
- Check the encoder for the damage. p. 262
- Restart the servo drive. p. 262
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 11 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 11; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.