Delta ASDA-B series Error ALE 11: Serial communication error

Delta ASDA-B series · taken from the manufacturer’s manual, pages cited

Error codeALE 11

A serial communication error occurs when RS-232/485 communication is faulty due to pulse signal or encoder wiring errors. The manual's first action is: “1. Check if all wiring is correct. 2. Check if the users conduct the wiring by the wiring information in the user manual.”

Model
Delta ASDA-B series
Display shows
Serial communication error (ALE 11)
Type
Error code
Source
Manual p. 256

What ALE 11 means

Serial communication error p. 262

Common causes

  • RS-232/485 serial communication is in error. p. 262
  • Pulse signal is in error. p. 262
  • The wiring of encoder is in error. p. 262
  • Encoder is loose p. 262
  • The wiring of encoder is defective. p. 262
  • Encoder is damage p. 262

What to do

  1. 1. Check if all wiring is correct. 2. Check if the users conduct the wiring by the wiring information in the user manual. p. 262
  2. Examine the encoder connector. p. 262
  3. Check if all connections are tight. p. 262
  4. Check the encoder for the damage. p. 262
  5. Restart the servo drive. p. 262

Before you service the product, read the safety instructions in the manual p. 3.

If ALE 11 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ALE 11; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.