A serial communication error occurs when RS-232/485 communication is faulty due to incorrect parameter settings or address. The manual's first action is: “Check the communication parameter setting. Correctly set parameter setting.”
- Model
- Delta ASDA-B series
- Display shows
- Serial communication error (ALE 10)
- Type
- Error code
- Source
- Manual p. 256
What ALE 10 means
Serial communication error p. 261
Common causes
- RS-232/485 serial communication is in error. p. 261
- Communication parameter setting is defective. p. 261
- Communication address is incorrect. p. 261
- Communication value is incorrect. p. 261
What to do
- Check the communication parameter setting. Correctly set parameter setting. p. 261
- Check the communication address. Correctly set communication address. p. 261
- Check the communication value. Correctly set communication value. p. 261
- Turn ARST (DI signal) ON to clear the fault. This fault message can also be removed automatically after the communication is normal. p. 261
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 10 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.