Delta ASDA-B series Error ALE 15: Reverse limit switch error

Delta ASDA-B series · taken from the manufacturer’s manual, pages cited

Error codeALE 15

A reverse limit switch error occurs when the reverse limit switch is activated or the servo system is unstable. The manual's first action is: “Check if forward limit switch is On or Off.”

Model
Delta ASDA-B series
Display shows
Reverse limit switch error (ALE 15)
Type
Error code
Source
Manual p. 256

What ALE 15 means

Reverse limit switch error p. 262

Common causes

  • Reverse limit switch is activated. p. 262
  • Forward limit switch is activated. p. 262
  • Servo system is not stable. p. 262

What to do

  1. Check if forward limit switch is On or Off. p. 262
  2. Check the value of control parameter setting and load inertia. p. 262
  3. Turn ARST (DI signal) ON to clear the fault or restart the servo drive. p. 262

Before you service the product, read the safety instructions in the manual p. 3.

If ALE 15 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ALE 15; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.