Delta ASDA-B series Error ALE 12: Encoder error (Position detector fault)

Delta ASDA-B series · taken from the manufacturer’s manual, pages cited

Error codeALE 12

An encoder error occurs when the pulse signal is incorrect, the adjusted value exceeds its limit during electrical adjustment, or the motor is running. The manual's first action is: “Check if the motor is running.”

Model
Delta ASDA-B series
Display shows
Encoder error (Position detector fault) (ALE 12)
Type
Error code
Source
Manual p. 256

What ALE 12 means

Encoder error (Position detector fault) p. 262

Common causes

  • Pulse signal is in error. p. 262
  • Adjusted value exceeds the limit of its allowable setting value when perform electrical adjustment. p. 262
  • The motor is running. p. 262
  • Analog input contact does not correctly return to zero. p. 262
  • Detection device may be damaged. p. 262

What to do

  1. Check if the motor is running. p. 262
  2. Measure and check if the voltage level of analog input contact is the same as the electrical potential of grounding. p. 262
  3. Check and reset the power supply. p. 262
  4. This fault message can be removed after the wiring of CN1 connector (I/O signal connector) is removed and auto adjustment function is executed. p. 262

Before you service the product, read the safety instructions in the manual p. 3.

If ALE 12 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about ALE 12; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.