The motor type error occurs when the motor capacity does not match the servo drive setting or the control power supply is incorrect. The manual's first action is: “Check the power cable and connections of R, S, T. Check whether the power cable is loose or the possible loss of phase on input power. If the fault does not clear even when the three-phase power is connected correctly, please contact your distributor for assistance or contact with Delta.”
- Model
- Delta ASDA-B series
- Display shows
- Motor type error (ALE 20)
- Type
- Error code
- Source
- Manual p. 256
What ALE 20 means
Motor type error p. 263
Common causes
- The motor capacity does not match the servo drive setting p. 263
- Control power supply is in error. p. 263
What to do
- Check the power cable and connections of R, S, T. Check whether the power cable is loose or the possible loss of phase on input power. If the fault does not clear even when the three-phase power is connected correctly, please contact your distributor for assistance or contact with Delta. p. 263
- This fault message can be removed automatically after input power phase lost problem is solved. p. 263
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 20 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 20; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.