The IGBT temperature error occurs when the IGBT temperature is too high or there is a data error in memory read-out or write-in. The manual's first action is: “Reset parameter or power supply. Please contact your distributor for assistance or contact with Delta.”
- Model
- Delta ASDA-B series
- Display shows
- IGBT temperature error (ALE 17)
- Type
- Error code
- Source
- Manual p. 256
What ALE 17 means
IGBT temperature error p. 263
Common causes
- The temperature of IGBT is over high. p. 263
- EE-PROM write-in and read-out is in error. p. 263
- Data error in Memory read-out / write-in. p. 263
What to do
- Reset parameter or power supply. Please contact your distributor for assistance or contact with Delta. p. 263
- Turn ARST (DI signal) ON to clear the fault or restart the servo drive. p. 263
Before you service the product, read the safety instructions in the manual p. 3.
If ALE 17 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about ALE 17; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.