Rexroth AA4VG Series 3 Manuals

ManualLib has 2 documents for the Rexroth AA4VG Series 3: 2 service manuals. Every file can be read online or downloaded as a PDF for free.

Service Manual 2

Key facts

Brand
Rexroth
Model
AA4VG Series 3
Documents
2
Languages
EN
Last added
2023-10-16

Start here

Rexroth AA4VG Series 3 Variable Displacement Pump Application and Service Manual

Rexroth AA4VG Series 3 Variable Displacement Pump Application and Service Manual

Service Manual 37 pages · 948 KB · EN

The document is an Application & Service Manual for the Rexroth AA4VG Series 3 variable displacement pump. It details ordering procedures, technical data including pressure ratings and fluid recommendations, and various configuration options such as control types and shaft options.

The guide provides comprehensive instructions for installation in any position around the horizontal axis, start-up procedures, and routine maintenance tasks like filter replacement and seal inspection. It also includes troubleshooting steps and specific adjustment procedures for relief valves and mechanical centering.

Read online

Rexroth AA4VG Series 3 specifications

Nominal Pressure (Port A or B)400 bar (5800 psi)
Peak Pressure (Port A or B)450 bar (6525 psi)
Maximum Case Drain Pressure2 bar abs. (30 psia)
Charge Pump Nominal Pressure20 bar (290 psi)
Operating Viscosity Range80...170 SUS (16...36 mm2/S)
Min. Operating Temperature-40°F (-25°C)

Source: Rexroth AA4VG Series 3 Variable Displacement Pump Application and Service Manual

All Rexroth AA4VG Series 3 documents by type

Questions answered in these manuals

What hydraulic fluid is recommended for the AA4VG pump?

The pumps are supplied as standard for use with good quality, petroleum oil based, anti-wear hydraulic fluids.

From: Rexroth AA4VG Series 3 Variable Displacement Pump Application and Service Manual

What is the minimum cleanliness level required for hydraulic fluid?

The hydraulic fluid must be maintained at a minimum cleanliness level of 18/15 (ISO/DIS 4406; SAE J1165).

From: Rexroth AA4VG Series 3 Variable Displacement Pump Application and Service Manual

What hydraulic fluid is recommended for standard operation?

The pumps are supplied as standard for use with good quality, petroleum oil based, anti-wear hydraulic fluids.

From: Rexroth AA4VG Series 3 Variable Displacement Pump Application & Service Manual

In which direction should the case drain line be connected?

The case drain line should be connected to the highest case drain port (T 1 or T2) so that the pump case always remains full of oil.

From: Rexroth AA4VG Series 3 Variable Displacement Pump Application & Service Manual