This document is the user manual and maintenance manual of AA4VG variable displacement pump, which contains the product model, parts information, etc.
The document is an Application & Service Manual for the Rexroth AA4VG Series 3 variable displacement pump. It details ordering procedures, technical data including pressure ratings and fluid recommendations, and various configuration options such as control types and shaft options.
The guide provides comprehensive instructions for installation in any position around the horizontal axis, start-up procedures, and routine maintenance tasks like filter replacement and seal inspection. It also includes troubleshooting steps and specific adjustment procedures for relief valves and mechanical centering.
| Nominal Pressure (Port A or B) | 400 bar (5800 psi) |
|---|---|
| Peak Pressure (Port A or B) | 450 bar (6525 psi) |
| Maximum Case Drain Pressure | 2 bar abs. (30 psia) |
| Charge Pump Nominal Pressure | 20 bar (290 psi) |
| Operating Viscosity Range | 80...170 SUS (16...36 mm2/S) |
| Min. Operating Temperature | -40°F (-25°C) |
The pumps are supplied as standard for use with good quality, petroleum oil based, anti-wear hydraulic fluids.
The hydraulic fluid must be maintained at a minimum cleanliness level of 18/15 (ISO/DIS 4406; SAE J1165).