This is a maintenance manual for AA4VG series variable displacement pumps.
The document is an Application & Service Manual for the Rexroth AA4VG Series 3 variable displacement pump. It details ordering procedures, technical data including pressure ratings and fluid recommendations, and specific installation requirements such as mounting orientation and case drain connections.
The guide provides comprehensive instructions for operation, start-up, and routine maintenance. It includes sections on troubleshooting, adjustments for relief valves and mechanical centering, removal of subassemblies like shaft seals and filters, and replacement procedures.
| Nominal pressure (port A or B) | 400 bar (5800 psi) |
|---|---|
| Peak pressure (port A or B) | 450 bar (6525 psi) |
| Maximum case drain pressure | 2 bar abs. (30 psia) |
| Charge pump nominal pressure | 20 bar (290 psi) |
| Operating Viscosity Range | 80...170 SUS (16...36 mm2/S) |
| Min. operating temperature | -13°F (-25°C) |
The pumps are supplied as standard for use with good quality, petroleum oil based, anti-wear hydraulic fluids.
The case drain line should be connected to the highest case drain port (T 1 or T2) so that the pump case always remains full of oil.
The hydraulic fluid must be maintained at a minimum cleanliness level of 18/15.