Rexroth AA4VG Series 3 Variable Displacement Pump Application & Service Manual

This is a maintenance manual for AA4VG series variable displacement pumps.


Rexroth AA4VG Series 3 Variable Displacement Pump Application & Service Manual - cover page
Brand
Rexroth
Document type
Service Manual
Language
English
Pages
40
File format
PDF
File size
973 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
831702BBF1820A2E1D33C053B037155A

About this manual

The document is an Application & Service Manual for the Rexroth AA4VG Series 3 variable displacement pump. It details ordering procedures, technical data including pressure ratings and fluid recommendations, and specific installation requirements such as mounting orientation and case drain connections.

The guide provides comprehensive instructions for operation, start-up, and routine maintenance. It includes sections on troubleshooting, adjustments for relief valves and mechanical centering, removal of subassemblies like shaft seals and filters, and replacement procedures.

What's inside

  • Ordering of Parts
  • Technical Data
  • Filtration Options
  • High Pressure Relief Valve
  • Pump Controls
  • Pump Installation
  • Start-up Procedure
  • Trouble Shooting Procedure
  • Charge Pressure Relief Adjustments
  • Routine Maintenance

Specifications

Nominal pressure (port A or B)400 bar (5800 psi)
Peak pressure (port A or B)450 bar (6525 psi)
Maximum case drain pressure2 bar abs. (30 psia)
Charge pump nominal pressure20 bar (290 psi)
Operating Viscosity Range80...170 SUS (16...36 mm2/S)
Min. operating temperature-13°F (-25°C)

Frequently asked questions

What hydraulic fluid is recommended for standard operation?

The pumps are supplied as standard for use with good quality, petroleum oil based, anti-wear hydraulic fluids.

In which direction should the case drain line be connected?

The case drain line should be connected to the highest case drain port (T 1 or T2) so that the pump case always remains full of oil.

What is the minimum cleanliness level required for hydraulic fluid?

The hydraulic fluid must be maintained at a minimum cleanliness level of 18/15.