Fluke 116 is a battery-powered true-rms multimeter with a 6000-count display and bar graph.
The Fluke 116 is a battery-powered true-rms multimeter with a 6000-count display and bar graph. It conforms to CAT III of the IEC 61010-1 2nd Edition safety standard.
This manual covers safety information, display symbols, terminals, error messages, rotary switch positions, and measurement ranges for the meter. This manual is written in Japanese.
| Safety rating | CAT III, IEC 61010-1 2nd Edition |
|---|---|
| AC voltage range | 0.06 V to 600 V |
| Frequency range | 5 Hz to 50 kHz |
| DC voltage range | 0.001 V to 600 V |
| AC mV range | 6.0 mV to 600 mV |
| DC mV range | 0.1 V to 600 mV |
| Resistance range | 0.1 Ω to 40 MΩ |
| Continuity | On below 20 Ω, off above 250 Ω |
| Temperature range | -40 °C to 400 °C (-40 °F to 752 °F) |
| Diode test | OL above 2.0 V |
| Capacitance range | 1 nF to 9999 µF |
| DC current range | 0.1 µA to 600 µA |
| AC current range | 6.0 µA to 600 µA |
| Dangerous voltage threshold | 30 V or more |
It appears when a voltage of 30 V or more is measured.
It conforms to CAT III of IEC 61010-1 2nd Edition.
Replace the battery before operating the meter.
The product is warranted for 3 years from the shipping date against material and manufacturing defects.