Flowline LZ12/LU10/LP15/LO10 Switch-Tek Powered Liquid Level Switches User Manual

Flowline LZ12/LU10/LP15/LO10 Switch-Tek Powered Liquid Level Switches User Manual

User Manual 20 pages · 1.1 MB · EN

This document provides instructions for Flowline Switch-Tek™ Powered Liquid Level Switches, covering four specific models: the Vibration type (LZ12), Ultrasonic type (LU10), Optic Leak Detection type (LO10), and Capacitance type (LP15). All series feature two outputs: a 4-20 mA current switch and a 60VA SPST dry contact relay. They are manufactured with thermoplastics for submersible use in corrosive environments.

Read online

Flowline LZ12 specifications

Supply voltage12-36 VDC (LZ12 Only: 12-30 VDC)
Contact rating60VA (125 VAC max / 1A max)
Process temperature-40° to 176°F (-40° to 80°C)
Pressure rating150 psi (10 bar) @ 25 °C.
Sensor ratingNEMA 6 (IP68)

Source: Flowline LZ12/LU10/LP15/LO10 Switch-Tek Powered Liquid Level Switches User Manual

All Flowline LZ12 documents by type

Questions answered in these manuals

What liquids will an LP15 series sensor detect?

The LP15 series is factory-calibrated for liquids with a dielectric value between 20 and 80. Liquids with a dielectric constant less than 20 will not be detected.

From: Flowline LZ12/LU10/LP15/LO10 Switch-Tek Powered Liquid Level Switches User Manual

How does the LZ12 Vibration switch detect liquid?

It operates at a nominal frequency of 400 Hz; immersion in liquid causes a frequency shift that indicates the presence of the medium.

From: Flowline LZ12/LU10/LP15/LO10 Switch-Tek Powered Liquid Level Switches User Manual

What are the four series of Switch-Tek powered level switches covered in this manual?

The manual covers Vibration (LZ12), Ultrasonic (LU10), Optic Leak (LO10) and SuperGuard Capacitance (LP15).

From: Flowline LZ12, LU10, LP15 and LO10 Powered Level Switch User Manual

What are the two output types for these level switches?

The switches feature a 4 or 20 mA current switch and a GOVA SPST dry contact relay.

From: Flowline LZ12, LU10, LP15 and LO10 Powered Level Switch User Manual

What liquids will the LP15 series sensor detect?

The LP15 series is factory-calibrated to be used with liquids having a dielectric value between 20 and 80.

From: Flowline LZ12/LU10/LP15/LO10 Series Switch-Tek Powered Liquid Level Switches User Manual

What liquids can the LP15 series capacitance switch detect?

The sensor is factory-calibrated to be used with liquids that have a dielectric value between 20 and 80.

From: Flowline LZ12/LU10/LP15/LO10 Series Switch-Tek Powered Liquid Level Switches User Manual