Flowline LV20 Manuals

ManualLib has 2 documents for the Flowline LV20: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
LV20
Industry
Industrial
Documents
2
Languages
EN
Last added
2023-10-12

Start here

Flowline LV20 and LH25 Mini-Float Liquid Level Switch User Manual

Flowline LV20 and LH25 Mini-Float Liquid Level Switch User Manual

User Manual 12 pages · 1.3 MB · EN

The document serves as a user guide for the Flowline LV20 (vertical) and LH25 (horizontal) Mini-Float Liquid Level Switches. It details the operating principle where a magnet on a buoyant float actuates a reed switch upon immersion in liquid.

Key sections cover safety precautions regarding installation torque and material compatibility, specific orientation requirements to ensure proper operation, electrical specifications including voltage limits and contact ratings, and wiring instructions for integration with Flowline controllers.

Read online

Flowline LV20 specifications

Accuracy in water±5mm
Repeatability in water±2mm
LV20 Contact Rating120VAC/VDC @ 50 VA
LV20 Temperature Range (F)-40˚ to 176˚
LV20 Pressure Range10 psi (0.7bar)
LH25 Pressure Range100 psi (6.9 bar)

Source: Flowline LV20 and LH25 Mini-Float Liquid Level Switch User Manual

All Flowline LV20 documents by type

Questions answered in these manuals

What is the maximum cable length for these switches?

The cable length may be extended up to a maximum of 500 feet using well insulated, shielded wire.

From: Flowline LV20 and LH25 Mini-Float Liquid Level Switch User Manual

What material is used for the wetted parts of the LH25-5201 model?

The LV20-52_1 and LH25-5201 switches are made of Polyvinylidene Fluoride (PVDF) with a Tetrafluoroethylene (TFE) cable.

From: Flowline LV20 and LH25 Mini-Float Liquid Level Switch User Manual

Can vertical switch stems be mounted at an angle?

Satisfactory operation is possible with the stem at up to a 30° angle from vertical.

From: Switch-Tek™ Horizontal, Vertical & Float-Point Float Switches AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

How should switches be installed?

Switches should be installed rigidly so the float or floats are free to move as the liquid level changes.

From: Switch-Tek™ Horizontal, Vertical & Float-Point Float Switches AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual