Key facts
- Brand
- FlowLine
- Model
- LO10
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2023-10-12
Start here

Flowline Switch-Tek Powered Level Switch LZ12, LU10, LP15 and LO10 Series User Manual
This document provides comprehensive operating instructions for four models of Flowline Switch-Tek™ powered level switches: Vibration (LZ12), Ultrasonic (LU10), Optic Leak Detection (LO10), and SuperGuard Capacitance (LP15). All units feature two outputs, a 4 or 20 mA current switch and a 60VA SPST dry contact relay, and are designed to be submersible in corrosive applications.
Read onlineFlowline LO10 specifications
| Supply voltage | 12-36 VDC (LZ12 Only: 12-30 VDC) |
|---|---|
| Contact rating | 60VA (125 VAC max / 1A max) |
| Accuracy | ± 1 mm in water |
| Repeatability | ± 0.5 mm in water |
| Process temperature range (F) | -40° to 176° F |
| Pressure rating | 150 psi (10 bar) @ 25 °C. |
Source: Flowline LZ12/LU10/LP15/LO10 Series Switch-Tek Powered Liquid Level Switches User Manual
All Flowline LO10 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What liquids will the LP15 series sensor detect?
The LP15 series is factory-calibrated to be used with liquids having a dielectric value between 20 and 80.
From: Flowline LZ12/LU10/LP15/LO10 Series Switch-Tek Powered Liquid Level Switches User Manual
What liquids can the LP15 series capacitance switch detect?
The sensor is factory-calibrated to be used with liquids that have a dielectric value between 20 and 80.
From: Flowline LZ12/LU10/LP15/LO10 Series Switch-Tek Powered Liquid Level Switches User Manual
What liquids will the LP15 series sensor detect?
The LP15 series is factory-calibrated to be used with liquids having a dielectric value between 20 and 80.
From: Flowline Switch-Tek Powered Level Switch LZ12, LU10, LP15 and LO10 Series User Manual
What happens if the LZ12 vibration switch becomes coated?
If coating prevents operation, the switch outputs a preventative maintenance alarm via the Yellow wire.
From: Flowline Switch-Tek Powered Level Switch LZ12, LU10, LP15 and LO10 Series User Manual