Flowline LZ12/LU10/LP15/LO10 Series Switch-Tek Powered Liquid Level Switches User Manual

This document provides detailed information on all four models of Flowline Switch-Tek™ powered level switches; Vibration (LZ12 series), Ultrasonic (LU10 series), Optic Leak (LO10 series) and SuperGuard Capacitance (LP15 series), including their specifications, sensor information, installation, electrical etc.


Flowline LZ12/LU10/LP15/LO10 Series Switch-Tek Powered Liquid Level Switches User Manual - cover page
Brand
FlowLine
Document type
User Manual
Language
English
Pages
19
File format
PDF
File size
703 KB
Published
12 October, 2023
Updated
12 October, 2023
MD5 checksum
41811B52AE2556D4ACC71317376CF2A6

About this manual

The document provides a comprehensive guide for the Switch-Tek™ Powered Liquid Level Switches, covering four distinct series: Vibration (LZ12), Ultrasonic (LU10), Optic Leak Detection (LO10), and SuperGuard Capacitance (LP15). All models feature two outputs: a 4 or 20 mA current switch and a 60VA SPST dry contact relay, manufactured with thermoplastics for submersible use in corrosive applications.

What's inside

  • Specifications
  • Sensor Information - Vibration Level Switch (LZ12 Series)
  • Maintenance Alarm (LZ12 Only)
  • Sensor Information - Ultrasonic Level Switch (LU10 Series)
  • Sensor Information - Optic Leak Detection Switch (LO10 Series)
  • Sensor Information - Capacitance Level Switch (LP15 Series)
  • Safety Precautions
  • Installation and Wiring

Specifications

Supply voltage12-36 VDC (LZ12 Only: 12-30 VDC)
Contact rating60VA (125 VAC max / 1A max)
Accuracy± 1 mm in water
Repeatability± 0.5 mm in water
Process temperature range (F)-40° to 176° F
Pressure rating150 psi (10 bar) @ 25 °C.

Frequently asked questions

What liquids will the LP15 series sensor detect?

The LP15 series is factory-calibrated to be used with liquids having a dielectric value between 20 and 80.

What liquids can the LP15 series capacitance switch detect?

The sensor is factory-calibrated to be used with liquids that have a dielectric value between 20 and 80.

What happens if the liquid has a dielectric constant less than 20?

Liquids with a dielectric constant less than 20 will not be detected by an LP15 series sensor.

What is the maximum supply voltage for the LZ12 series?

The LZ12 series requires a supply voltage of 12-30 VDC.