Flowline LU81 Manuals

ManualLib has 2 documents for the Flowline LU81 (Other Electronics): 1 user manual, 1 quick start guide. Every file can be read online or downloaded as a PDF for free.

User Manual 1Quick Start Guide 1

Key facts

Model
LU81
Industry
Industrial
Documents
2
Languages
EN
Last added
2023-10-12

Start here

Flowline LU81/LU83/LU84 Ultrasonic Liquid Level Transmitter Quick Start

Flowline LU81/LU83/LU84 Ultrasonic Liquid Level Transmitter Quick Start

Quick Start Guide 8 pages · 371 KB · EN

This document provides basic mounting, setup, and use instructions for the EchoSpan ultrasonic liquid level transmitter, covering the LU81, LU83, and LU84 series. It includes guidance on selecting appropriate tank adapters, risers, and stand-pipes to ensure accurate measurements and optimal performance.

Read online

Flowline LU81 specifications

Range Accuracy± 0.2% of range
Supply Voltage14-28 VDC
Signal Output4-20 mA, two-wire
Enclosure RatingNEMA 4X (IP65)
Transducer MaterialPVDF, Viton

Source: Flowline EchoSpan LU80/LU81/LU83/LU84 Series Ultrasonic Liquid Level Transmitter User Manual

All Flowline LU81 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What is the factory default display mode?

The factory default configuration displays the level of liquid in the tank.

From: Flowline EchoSpan LU80/LU81/LU83/LU84 Series Ultrasonic Liquid Level Transmitter User Manual

How do you reverse the current output?

Select REV mode in the TANK menu setting to invert the 4 and 20 mA set points.

From: Flowline EchoSpan LU80/LU81/LU83/LU84 Series Ultrasonic Liquid Level Transmitter User Manual

What are the supported units for the EchoSpan?

The sensor displays information in inches, feet, centimeters, meters, or percentage.

From: Flowline LU81/LU83/LU84 Ultrasonic Liquid Level Transmitter Quick Start

What is the minimum and maximum cable diameter for using the Flowline LM90-1001 liquid tight fitting?

The cable minimum is 0.170" (4.3mm) and the maximum is 0.450" (11.4mm).

From: Flowline LU81/LU83/LU84 Ultrasonic Liquid Level Transmitter Quick Start