Key facts
- Brand
- FlowLine
- Model
- LV10 Series
- Category
- Other Electronics
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2023-10-12
Start here

Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual
This manual provides instructions for the Flowline LV10 Series Vertical Buoyancy Liquid Level Switch. The device utilizes a float, magnet, and reed switch mechanism to detect liquid levels. When the probe is dry, the float rests on the bottom, keeping the reed switch inactive. As the probe immerses in liquid, buoyancy lifts the float, activating the switch.
Read onlineFlowline LV10 Series specifications
| Accuracy | ±2mm in water |
|---|---|
| Repeatability | ±1mm in water |
| Orientation | ±20˚ from vertical |
| Specific Gravity | 0.8 minimum |
| Contact Rating | 15VA, 0.25A max. |
| Contact Voltage | 120 VAC, 120 VDC @ 15 VA |
| Temperature Range | -40˚ to 80˚ C |
| Pressure Range | 25 psi (2 bar) @ 25˚ C. |
| Sensor Material | Polypropylene (PP) or PVDF |
| Cable Length | 10' (3m) |
Source: Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual
All Flowline LV10 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the maximum supply voltage for the LV10 switch?
The supply voltage should never exceed 120 volts AC @ 15 VA for the LV10-_3_1 model.
From: Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual
Can the LV10 series be used in hazardous applications?
It should not be used within flammable or explosive applications unless properly connected to an approved control device.
From: Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual
What is the maximum supply voltage for the LV10 switch?
The supply voltage should never exceed 120 volts AC @ 15 VA for the standard model, or 30 VRMS and 42.4 Vpeak for CE versions.
From: Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual
Can the LV10 be used in flammable or explosive applications?
No, it should not be used in such applications unless properly connected to an approved control device.
From: Flowline LV10 Series Vertical Buoyancy Liquid Level Switch Manual