Flowline Switch-Tek Powered Level Switch LZ12, LU10, LP15 and LO10 Series User Manual

This manual contains information on all four models of Flowline Switch-Tek™ powered level switches; Vibration (LZ12 series), Ultrasonic (LU10 series), Optic Leak (LO10 series) and SuperGuard Capacitance (LP15 series).


Flowline Switch-Tek Powered Level Switch LZ12, LU10, LP15 and LO10 Series User Manual - cover page
Brand
FlowLine
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
1.9 MB
Published
12 October, 2023
Updated
12 October, 2023
MD5 checksum
6E7765FDEBD61F57B6AC5DBDC17CA58B

About this manual

This document provides comprehensive operating instructions for four models of Flowline Switch-Tek™ powered level switches: Vibration (LZ12), Ultrasonic (LU10), Optic Leak Detection (LO10), and SuperGuard Capacitance (LP15). All units feature two outputs, a 4 or 20 mA current switch and a 60VA SPST dry contact relay, and are designed to be submersible in corrosive applications.

What's inside

  • Introduction
  • Specifications
  • Vibration Switch (LZ12 Series)
  • Maintenance Alarm
  • Ultrasonic Switch (LU10 Series)
  • Optic Leak Detection (LO10 Series)
  • SuperGuard Capacitance Switch (LP15 Series)
  • Safety Precautions
  • Installation
  • Wiring

Specifications

Accuracy± 1 mm in water
Repeatability± 0.5 mm in water
Supply voltage12-36 VDC (LZ12 Only: 12-30 VDC)
Contact rating60VA (125 VAC max / 1A max)
Pressure150 psi (10 bar) @ 25 °C.
Sensor ratingNEMA 6 (IP68)

Frequently asked questions

What liquids will the LP15 series sensor detect?

The LP15 series is factory-calibrated to be used with liquids having a dielectric value between 20 and 80.

What happens if the LZ12 vibration switch becomes coated?

If coating prevents operation, the switch outputs a preventative maintenance alarm via the Yellow wire.